Air Receiver

Pioneers in the industry, we offer vertical air receiver, ss vertical air receiver tank 1000 l, vertical air receiver tank, air pressure tank and high pressure air tank from India.

Vertical Air Receiver

Request Callback

₹ 95000 / Piece Get Latest Price

Product Brochure
Storage Volume1000 L
Storage Capacity1500 L
Design Pressure10 bar
Material GradeIS 2062
Tank CoatingRed Oxide Primer
Mounting TypeLeg Mounted
Tank OrientationVertical
Storage Capacity(litre)1500 L
MaterialMS
Pressure Rating(psi)150
CertificationIS 2825
Connection Size2 inch
Surface FinishPainted
Country of OriginMade in India

Minimum order quantity: 1 Piece

1. General
  • Type: Air Receiver Tank (Compressed Air Storage)

  • Orientation: Vertical / Horizontal

  • Application: Industrial / Commercial / Utility

  • Mounting: Skid / Leg-supported / Saddle base

  • Location: Indoor / Outdoor

2. Capacity & Dimensions
  • Volume: e.g., 250 L, 500 L, 1000 L, 50,000 L,

  • Working Pressure: e.g., 8 bar / 10 bar / 16 bar

  • Design Pressure: Typically 1.3 × working pressure

  • Diameter & Height / Length

  • Wall Thickness

3. Material of Construction
  • Shell & Heads: Carbon Steel / Stainless Steel

  • Internal Surface: Painted / Bare / Lined (optional)

  • External Surface: Epoxy primer + PU paint / Powder-coated

  • Corrosion Allowance: e.g., 1.5 mm

4. Design Standards
  • Design Code: ASME Section VIII Div 1 / IS 2825 / PED / CE

  • Test Pressure: 1.5 × Design Pressure

  • Temperature Range: e.g., -10°C to 100°C

5. Nozzles & Openings
  • Air Inlet

  • Air Outlet

  • Drain Valve (manual or auto)

  • Safety Valve Port

  • Pressure Gauge Port

  • Manhole / Inspection Opening (for large tanks)

6. Fittings & Accessories
  • Safety Relief Valve

  • Pressure Gauge

  • Drain Valve (ball / auto drain)

  • Air Filter / Moisture Trap (optional)

  • Level Indicator (if required)

7. Supports
  • Vertical Tank: Legs or skirt

  • Horizontal Tank: Saddle base

  • Foundation Bolts: Yes / No

  • Lifting Lugs: Yes / No

8. Surface Finish
  • Internal: Anti-corrosive / Bare

  • External: Epoxy painted / Powder coated

  • Surface Prep: SA 2.5 (if painted)

9. Testing & Inspection
  • Hydrotest: 1.5 × Design Pressure

  • Pneumatic Test: Optional

  • NDT (if required): Radiography / UT / MPI

  • Visual & Dimensional Check

10. Documentation
  • Datasheet & GA Drawing

  • Material Test Certificates (MTC)

  • WPS / PQR / Welder Qualification

  • Test Reports: Hydro / NDT

  • Pressure Vessel Certification (if required)

  • User Manual / O&M Guide

SS Vertical Air Receiver Tank 1000 L

Request Callback

₹ 130000 / Piece Get Latest Price

Product Brochure
Storage Volume1000 L
Storage Capacity1000 L
Design Pressure10 bar
Material GradeIS 2002
Tank OrientationVertical
Storage Capacity(litre)1000 L
MaterialSS
Pressure Rating(psi)150
Country of OriginMade in India

Minimum order quantity: 1 Piece

  1. Tank Type: Horizontal or Vertical High Pressure Storage Tank

  2. Material of Construction: Stainless Steel 

  3. Design Code: ASME Section VIII Div.1 / IS 2825

  4. Design Pressure: Up to 100 bar (as per requirement)

  5. Working Pressure: Typically 80–90% of design pressure

  6. Hydrotest Pressure: 1.5 × Design Pressure

  7. Design Temperature: -10°C to +150°C (typical)

  8. Corrosion Allowance: Minimum 1.5 mm

  9. Radiography: 100% / Spot – Based on critical weld joints

  10. Joint Efficiency: As per welding and code (typically 0.85 – 1.0)

  11. Shell & Head Thickness: As per design calculation

  12. End Closures: Dished / Torispherical / Ellipsoidal Heads

  13. Nozzles: As per process requirement – MS or CS (ASTM A106 Gr. B)

  14. Manhole: Provided – Typically 18" or 24"

  15. Supports: Skirt / Saddle / Leg type based on tank orientation

  16. Welding Process: SMAW / SAW / GTAW

  17. Post Weld Heat Treatment (PWHT): As required by code

  18. NDT Requirements:

    • Visual Testing (VT)

    • Radiography Testing (RT)

    • Dye Penetrant Testing (DPT)

    • Ultrasonic Testing (UT) – if applicable

  19. Surface Preparation: SA 2.5 (Abrasive Blasting)

  20. Painting (External):

    • Primer: Zinc Rich Epoxy

    • Top Coat: Polyurethane / as per client spec

    • DFT: Minimum 200 microns

  21. Internal Coating: None / Epoxy (if fluid is corrosive)

  22. Fittings & Accessories:

    • Pressure Gauge

    • Safety Relief Valve

    • Drain & Vent Nozzles

    • Earthing Lugs

    • Name Plate (SS)

  23. Inspection:

    • By Manufacturer QC

    • Third Party Inspection (if required)

  24. Documentation:

    • GA & Fabrication Drawings

    • Design Calculations

    • WPS/PQR/Welder Qualifications

    • MTCs & Test Reports

    • Hydrotest Certificate

    • Final Documentation Dossier (MDR)

Vertical Air Receiver Tank

Request Callback

₹ 45000 / Piece Get Latest Price

Product Brochure
Storage Capacity100 L
Tank OrientationVertical
Storage Capacity(litre)100 L
MaterialMS
Pressure Rating(psi)100
Country of OriginMade in India

Minimum order quantity: 1 Piece

1. General
  • Type: Air Receiver Tank (Compressed Air Storage)

  • Orientation: Vertical / Horizontal

  • Application: Industrial / Commercial / Utility

  • Mounting: Skid / Leg-supported / Saddle base

  • Location: Indoor / Outdoor

2. Capacity & Dimensions
  • Volume: e.g., 250 L, 500 L, 1000 L, 3000 L, etc.

  • Working Pressure: e.g., 8 bar / 10 bar / 16 bar

  • Design Pressure: Typically 1.3 × working pressure

  • Diameter & Height / Length

  • Wall Thickness

3. Material of Construction
  • Shell & Heads: Carbon Steel / Stainless Steel

  • Internal Surface: Painted / Bare / Lined (optional)

  • External Surface: Epoxy primer + PU paint / Powder-coated

  • Corrosion Allowance: e.g., 1.5 mm

4. Design Standards
  • Design Code: ASME Section VIII Div 1 / IS 2825 / PED / CE

  • Test Pressure: 1.5 × Design Pressure

  • Temperature Range: e.g., -10°C to 100°C

5. Nozzles & Openings
  • Air Inlet

  • Air Outlet

  • Drain Valve (manual or auto)

  • Safety Valve Port

  • Pressure Gauge Port

  • Manhole / Inspection Opening (for large tanks)

6. Fittings & Accessories
  • Safety Relief Valve

  • Pressure Gauge

  • Drain Valve (ball / auto drain)

  • Air Filter / Moisture Trap (optional)

  • Level Indicator (if required)

7. Supports
  • Vertical Tank: Legs or skirt

  • Horizontal Tank: Saddle base

  • Foundation Bolts: Yes / No

  • Lifting Lugs: Yes / No

8. Surface Finish
  • Internal: Anti-corrosive / Bare

  • External: Epoxy painted / Powder coated

  • Surface Prep: SA 2.5 (if painted)

9. Testing & Inspection
  • Hydrotest: 1.5 × Design Pressure

  • Pneumatic Test: Optional

  • NDT (if required): Radiography / UT / MPI

  • Visual & Dimensional Check

10. Documentation
  • Datasheet & GA Drawing

  • Material Test Certificates (MTC)

  • WPS / PQR / Welder Qualification

  • Test Reports: Hydro / NDT

  • Pressure Vessel Certification (if required)

  • User Manual / O&M Guide

Air Pressure Tank

Request Callback

₹ 55000 / Piece Get Latest Price

Product Brochure
Storage Capacity(litre)250 L
Storage MaterialGases
BrandTecnicon Engineering
MaterialMS
Tank OrientationVertical
Country of OriginMade in India

Minimum order quantity: 1 Piece

Basic Information
  • Tank Type: Vertical / Horizontal

  • Service: (Air, Nitrogen, Water, CO₂, Ammonia)

  • Capacity: (500 Liters / 50 m³)

  • Design Pressure: (0.5 bar, 35 bar)

  • Design Temperature: (-10°C to +50°C)

2. Construction
  • Shell Material: (Carbon Steel SA 516 Gr. 70 / SS 304 / SS 316)

  • Head Type: Ellipsoidal / Hemispherical / Dished End

  • Corrosion Allowance: (1.5 mm)

  • Thickness: As per design (ASME / IS / PED)

  • Internal Lining: Epoxy / Rubber / PTFE (if applicable)

3. Design Code / Standards
  • Applicable Codes:

    • ASME Sec VIII Div. 1

    • IS 2825

    • PED 2014/68/EU

    • API 650 / API 620 (for low pressure)

  • Testing Standards: Hydrostatic / Pneumatic tests as per ASME / customer spec

4. Connections / Nozzles
  • Inlet / Outlet Size and Type: (2” NPT / Flanged 150# RF)

  • Manhole: (450 mm Dia, top-mounted)

  • Drain: (1” BSP / NPT at bottom)

  • Vent: (1” NPT at top)

  • Pressure Relief Valve Nozzle: (size and rating)

  • Instrumentation Ports:

    • Pressure gauge

    • Temperature gauge

    • Level gauge / level switches (if applicable)

5. Supports and Mounting
  • Support Type: Skirt / Legs / Saddle

  • Anchor Pads: If required

  • Foundation Requirements: As per structural drawing

6. Surface Finish
  • Internal Surface:

    • Sandblasted, painted, or coated as required

    • Food grade (if SS) or chemical resistant coating (if for chemicals)

  • External Surface:

    • Primer + Finish paint system (epoxy / polyurethane)

    • Color code per industry standards (Blue for air, Yellow for fuel)

7. Accessories
  • Safety Relief Valve

  • Pressure Gauge with Syphon

  • Level Indicator (if applicable)

  • Drain Valve / Isolation Valve

  • Air Vent Valve

8. Inspection & Testing
  • Non-Destructive Testing:

    • Radiography / Dye Penetrant Test / Ultrasonic (as applicable)

  • Hydrostatic Test Pressure: 1.3x Design Pressure

  • Pneumatic Test (if applicable)

  • Third-party Inspection: (if required – Lloyd’s, BV, TUV)

9. Documentation
  • Material Test Certificates (MTCs)

  • Pressure Test Report

  • Welding Procedure Qualification Records (WPQR)

  • Drawings (General Arrangement & Fabrication)

  • Operation & Maintenance Manual

  • Certificate of Conformity (CoC)

10. Optional Features
  • Heating Jacket / Coil

  • Insulation: Type (e.g., Glass Wool), Thickness, Cladding

  • Agitator (for process tanks)

  • Level Transmitter / Digital Sensors

  • Skid Mounting (for mobile tanks)

High Pressure Air Tank

Request Callback

₹ 85000 / Piece Get Latest Price

Product Brochure
Storage Capacity(litre)1000 L
BrandTecnicon Engineering
MaterialMS
Tank OrientationVertical
Country of OriginMade in India

Minimum order quantity: 1 Piece

  1. Basic Info

    • Service Fluid: Air, Nitrogen, CO₂, Hydrogen, etc.

    • Capacity: 500 Liters to 50 m³, etc.

    • Design Pressure: 200 bar, 3000 psi

    • Design Temperature: -20°C to +65°C

  2. Design Code

    • ASME Sec VIII Div. 1 / Div. 2

    • PED, DOT, ISO 11120, TPED

  3. Material

    • Shell: Carbon Steel, Stainless Steel, Alloy Steel

    • Heads: Hemispherical, Ellipsoidal

    • Corrosion Allowance: 1.5 mm

  4. Connections

    • Inlet / Outlet: NPT, Flanged

    • Safety Valve Nozzle

    • Vent and Drain

    • Instrument Ports: Pressure, Temperature, Level

  5. Testing

    • Hydrostatic Test: 1.3 × Design Pressure

    • NDT: Radiography, Dye Penetrant, Ultrasonic Testing

    • Third-Party Inspection

  6. Finish

    • Internal: Epoxy Coated, Pickled, Passivated

    • External: Sandblasted and Painted, Color Coded

  7. Supports

    • Support Type: Skirt, Legs, Saddle

    • Designed for Seismic and Wind Load

  8. Accessories

    • Safety Relief Valve

    • Pressure Gauge

    • Temperature Gauge

    • Rupture Disc

  9. Documentation

    • Design Drawings

    • Material Certificates

    • Test Reports

    • Inspection Certificates

    • Operation & Maintenance Manual


X

Contact Us

Kishan Patel (CEO)
Tecnicon Engineering Private Limited
148, Amarnath Industrial Park, Indore Highway Road, Bhavda
Ahmedabad - 382433, Gujarat, India

Get Directions
Send Email
Share: