Pioneers in the industry, we offer vertical air receiver, ss vertical air receiver tank 1000 l, vertical air receiver tank, air pressure tank and high pressure air tank from India.
₹ 95000 / Piece Get Latest Price
| Storage Volume | 1000 L |
| Storage Capacity | 1500 L |
| Design Pressure | 10 bar |
| Material Grade | IS 2062 |
| Tank Coating | Red Oxide Primer |
| Mounting Type | Leg Mounted |
| Tank Orientation | Vertical |
| Storage Capacity(litre) | 1500 L |
| Material | MS |
| Pressure Rating(psi) | 150 |
| Certification | IS 2825 |
| Connection Size | 2 inch |
| Surface Finish | Painted |
| Country of Origin | Made in India |
Minimum order quantity: 1 Piece
Type: Air Receiver Tank (Compressed Air Storage)
Orientation: Vertical / Horizontal
Application: Industrial / Commercial / Utility
Mounting: Skid / Leg-supported / Saddle base
Location: Indoor / Outdoor
Volume: e.g., 250 L, 500 L, 1000 L, 50,000 L,
Working Pressure: e.g., 8 bar / 10 bar / 16 bar
Design Pressure: Typically 1.3 × working pressure
Diameter & Height / Length
Wall Thickness
Shell & Heads: Carbon Steel / Stainless Steel
Internal Surface: Painted / Bare / Lined (optional)
External Surface: Epoxy primer + PU paint / Powder-coated
Corrosion Allowance: e.g., 1.5 mm
Design Code: ASME Section VIII Div 1 / IS 2825 / PED / CE
Test Pressure: 1.5 × Design Pressure
Temperature Range: e.g., -10°C to 100°C
Air Inlet
Air Outlet
Drain Valve (manual or auto)
Safety Valve Port
Pressure Gauge Port
Manhole / Inspection Opening (for large tanks)
Safety Relief Valve
Pressure Gauge
Drain Valve (ball / auto drain)
Air Filter / Moisture Trap (optional)
Level Indicator (if required)
Vertical Tank: Legs or skirt
Horizontal Tank: Saddle base
Foundation Bolts: Yes / No
Lifting Lugs: Yes / No
Internal: Anti-corrosive / Bare
External: Epoxy painted / Powder coated
Surface Prep: SA 2.5 (if painted)
Hydrotest: 1.5 × Design Pressure
Pneumatic Test: Optional
NDT (if required): Radiography / UT / MPI
Visual & Dimensional Check
Datasheet & GA Drawing
Material Test Certificates (MTC)
WPS / PQR / Welder Qualification
Test Reports: Hydro / NDT
Pressure Vessel Certification (if required)
User Manual / O&M Guide
₹ 130000 / Piece Get Latest Price
| Storage Volume | 1000 L |
| Storage Capacity | 1000 L |
| Design Pressure | 10 bar |
| Material Grade | IS 2002 |
| Tank Orientation | Vertical |
| Storage Capacity(litre) | 1000 L |
| Material | SS |
| Pressure Rating(psi) | 150 |
| Country of Origin | Made in India |
Minimum order quantity: 1 Piece
Tank Type: Horizontal or Vertical High Pressure Storage Tank
Material of Construction: Stainless Steel
Design Code: ASME Section VIII Div.1 / IS 2825
Design Pressure: Up to 100 bar (as per requirement)
Working Pressure: Typically 80–90% of design pressure
Hydrotest Pressure: 1.5 × Design Pressure
Design Temperature: -10°C to +150°C (typical)
Corrosion Allowance: Minimum 1.5 mm
Radiography: 100% / Spot – Based on critical weld joints
Joint Efficiency: As per welding and code (typically 0.85 – 1.0)
Shell & Head Thickness: As per design calculation
End Closures: Dished / Torispherical / Ellipsoidal Heads
Nozzles: As per process requirement – MS or CS (ASTM A106 Gr. B)
Manhole: Provided – Typically 18" or 24"
Supports: Skirt / Saddle / Leg type based on tank orientation
Welding Process: SMAW / SAW / GTAW
Post Weld Heat Treatment (PWHT): As required by code
NDT Requirements:
Visual Testing (VT)
Radiography Testing (RT)
Dye Penetrant Testing (DPT)
Ultrasonic Testing (UT) – if applicable
Surface Preparation: SA 2.5 (Abrasive Blasting)
Painting (External):
Primer: Zinc Rich Epoxy
Top Coat: Polyurethane / as per client spec
DFT: Minimum 200 microns
Internal Coating: None / Epoxy (if fluid is corrosive)
Fittings & Accessories:
Pressure Gauge
Safety Relief Valve
Drain & Vent Nozzles
Earthing Lugs
Name Plate (SS)
Inspection:
By Manufacturer QC
Third Party Inspection (if required)
Documentation:
GA & Fabrication Drawings
Design Calculations
WPS/PQR/Welder Qualifications
MTCs & Test Reports
Hydrotest Certificate
Final Documentation Dossier (MDR)
₹ 45000 / Piece Get Latest Price
| Storage Capacity | 100 L |
| Tank Orientation | Vertical |
| Storage Capacity(litre) | 100 L |
| Material | MS |
| Pressure Rating(psi) | 100 |
| Country of Origin | Made in India |
Minimum order quantity: 1 Piece
Type: Air Receiver Tank (Compressed Air Storage)
Orientation: Vertical / Horizontal
Application: Industrial / Commercial / Utility
Mounting: Skid / Leg-supported / Saddle base
Location: Indoor / Outdoor
Volume: e.g., 250 L, 500 L, 1000 L, 3000 L, etc.
Working Pressure: e.g., 8 bar / 10 bar / 16 bar
Design Pressure: Typically 1.3 × working pressure
Diameter & Height / Length
Wall Thickness
Shell & Heads: Carbon Steel / Stainless Steel
Internal Surface: Painted / Bare / Lined (optional)
External Surface: Epoxy primer + PU paint / Powder-coated
Corrosion Allowance: e.g., 1.5 mm
Design Code: ASME Section VIII Div 1 / IS 2825 / PED / CE
Test Pressure: 1.5 × Design Pressure
Temperature Range: e.g., -10°C to 100°C
Air Inlet
Air Outlet
Drain Valve (manual or auto)
Safety Valve Port
Pressure Gauge Port
Manhole / Inspection Opening (for large tanks)
Safety Relief Valve
Pressure Gauge
Drain Valve (ball / auto drain)
Air Filter / Moisture Trap (optional)
Level Indicator (if required)
Vertical Tank: Legs or skirt
Horizontal Tank: Saddle base
Foundation Bolts: Yes / No
Lifting Lugs: Yes / No
Internal: Anti-corrosive / Bare
External: Epoxy painted / Powder coated
Surface Prep: SA 2.5 (if painted)
Hydrotest: 1.5 × Design Pressure
Pneumatic Test: Optional
NDT (if required): Radiography / UT / MPI
Visual & Dimensional Check
Datasheet & GA Drawing
Material Test Certificates (MTC)
WPS / PQR / Welder Qualification
Test Reports: Hydro / NDT
Pressure Vessel Certification (if required)
User Manual / O&M Guide
₹ 55000 / Piece Get Latest Price
| Storage Capacity(litre) | 250 L |
| Storage Material | Gases |
| Brand | Tecnicon Engineering |
| Material | MS |
| Tank Orientation | Vertical |
| Country of Origin | Made in India |
Minimum order quantity: 1 Piece
Tank Type: Vertical / Horizontal
Service: (Air, Nitrogen, Water, CO₂, Ammonia)
Capacity: (500 Liters / 50 m³)
Design Pressure: (0.5 bar, 35 bar)
Design Temperature: (-10°C to +50°C)
Shell Material: (Carbon Steel SA 516 Gr. 70 / SS 304 / SS 316)
Head Type: Ellipsoidal / Hemispherical / Dished End
Corrosion Allowance: (1.5 mm)
Thickness: As per design (ASME / IS / PED)
Internal Lining: Epoxy / Rubber / PTFE (if applicable)
Applicable Codes:
ASME Sec VIII Div. 1
IS 2825
PED 2014/68/EU
API 650 / API 620 (for low pressure)
Testing Standards: Hydrostatic / Pneumatic tests as per ASME / customer spec
Inlet / Outlet Size and Type: (2” NPT / Flanged 150# RF)
Manhole: (450 mm Dia, top-mounted)
Drain: (1” BSP / NPT at bottom)
Vent: (1” NPT at top)
Pressure Relief Valve Nozzle: (size and rating)
Instrumentation Ports:
Pressure gauge
Temperature gauge
Level gauge / level switches (if applicable)
Support Type: Skirt / Legs / Saddle
Anchor Pads: If required
Foundation Requirements: As per structural drawing
Internal Surface:
Sandblasted, painted, or coated as required
Food grade (if SS) or chemical resistant coating (if for chemicals)
External Surface:
Primer + Finish paint system (epoxy / polyurethane)
Color code per industry standards (Blue for air, Yellow for fuel)
Safety Relief Valve
Pressure Gauge with Syphon
Level Indicator (if applicable)
Drain Valve / Isolation Valve
Air Vent Valve
Non-Destructive Testing:
Radiography / Dye Penetrant Test / Ultrasonic (as applicable)
Hydrostatic Test Pressure: 1.3x Design Pressure
Pneumatic Test (if applicable)
Third-party Inspection: (if required – Lloyd’s, BV, TUV)
Material Test Certificates (MTCs)
Pressure Test Report
Welding Procedure Qualification Records (WPQR)
Drawings (General Arrangement & Fabrication)
Operation & Maintenance Manual
Certificate of Conformity (CoC)
Heating Jacket / Coil
Insulation: Type (e.g., Glass Wool), Thickness, Cladding
Agitator (for process tanks)
Level Transmitter / Digital Sensors
Skid Mounting (for mobile tanks)
₹ 85000 / Piece Get Latest Price
| Storage Capacity(litre) | 1000 L |
| Brand | Tecnicon Engineering |
| Material | MS |
| Tank Orientation | Vertical |
| Country of Origin | Made in India |
Minimum order quantity: 1 Piece
Basic Info
Service Fluid: Air, Nitrogen, CO₂, Hydrogen, etc.
Capacity: 500 Liters to 50 m³, etc.
Design Pressure: 200 bar, 3000 psi
Design Temperature: -20°C to +65°C
Design Code
ASME Sec VIII Div. 1 / Div. 2
PED, DOT, ISO 11120, TPED
Material
Shell: Carbon Steel, Stainless Steel, Alloy Steel
Heads: Hemispherical, Ellipsoidal
Corrosion Allowance: 1.5 mm
Connections
Inlet / Outlet: NPT, Flanged
Safety Valve Nozzle
Vent and Drain
Instrument Ports: Pressure, Temperature, Level
Testing
Hydrostatic Test: 1.3 × Design Pressure
NDT: Radiography, Dye Penetrant, Ultrasonic Testing
Third-Party Inspection
Finish
Internal: Epoxy Coated, Pickled, Passivated
External: Sandblasted and Painted, Color Coded
Supports
Support Type: Skirt, Legs, Saddle
Designed for Seismic and Wind Load
Accessories
Safety Relief Valve
Pressure Gauge
Temperature Gauge
Rupture Disc
Documentation
Design Drawings
Material Certificates
Test Reports
Inspection Certificates
Operation & Maintenance Manual
Kishan Patel (CEO)
Tecnicon Engineering Private Limited
148, Amarnath Industrial Park, Indore Highway Road, Bhavda
Ahmedabad - 382433, Gujarat, India