Our product range includes a wide range of ms fuel storage tank, underground fuel storage tank, diesel storage tank and edible oil storage tank.
₹ 195000 / Piece Get Latest Price
| Storage Capacity(L) | 9000 L |
| Tank Material | Mild Steel |
| Color | Light blue |
| Shape | Cylindrical type |
| Features | Horizontal |
| Size | 9000 L |
| Design | Fuel Tank |
| Height | 3000 MM |
| Leak Proof | Yes |
| Max Pressure Psi | 250 |
Minimum order quantity: 1 Piece
Type: Horizontal cylindrical, double-walled
Installation: Underground (buried)
Capacity: Typically ranges from 5,000 to 50,000 liters (1,300 to 13,000 gallons)
Material:
Primary: Steel
Secondary containment: FRP jacket or steel with corrosion-resistant coating
Environmental Compliance: EPA (U.S.), local environmental protection regulations
Fire Safety: NFPA 30 / 31 / 385
Double-wall construction for leak detection and secondary containment
Corrosion protection:
External: Protective coating or cathodic protection (for steel tanks)
Internal: Epoxy lining (optional)
Manways: 1 or 2 units (typically 600 mm or 24 inches diameter)
Internal Baffles: As required to minimize fuel movement (sloshing)
Anchor points: For buoyancy resistance
Fuel inlet/outlet connections (e.g., 2" to 4" threaded or flanged)
Vent pipe connection (usually 2" diameter)
Fill pipe with spill containment
Overfill prevention valve
Leak detection port
Level gauge connection (manual dipstick or automatic level gauge)
Emergency vent (pressure relief)
Interstitial space monitoring via:
Vacuum or pressure system
Liquid/brine detection sensor
Electronic monitoring system
Access chamber / tank sump for valves and fittings
Fill point containment box
Vent caps with flame arrestors
Tank gauging system (e.g., ATG – Automatic Tank Gauge)
Overfill alarms
Backfill: Washed pea gravel or sand per manufacturer’s spec
Hydrostatic or pneumatic pressure testing
Leak test of interstitial space
Calibration of tank gauge
Inspection and certification by approved authority
₹ 215000 / Piece Get Latest Price
| Storage Capacity(L) | 10000 L |
| Tank Material | Carbon Steel |
| Color | Blue |
| Shape | Horizontal Cylindrical |
| Country of Origin | Made in India |
Minimum order quantity: 1 Piece
Type: Horizontal cylindrical, double-walled
Installation: Underground (buried)
Capacity: Typically ranges from 5,000 to 50,000 liters (1,300 to 13,000 gallons)
Material:
Primary: Steel or fiberglass-reinforced plastic (FRP)
Secondary containment: FRP jacket or steel with corrosion-resistant coating
Environmental Compliance: EPA (U.S.), local environmental protection regulations
Fire Safety: NFPA 30 / 31 / 385
Double-wall construction for leak detection and secondary containment
Corrosion protection:
External: Protective coating or cathodic protection (for steel tanks)
Internal: Epoxy lining (optional)
Manways: 1 or 2 units (typically 600 mm or 24 inches diameter)
Internal Baffles: As required to minimize fuel movement (sloshing)
Anchor points: For buoyancy resistance
Fuel inlet/outlet connections (e.g., 2" to 4" threaded or flanged)
Vent pipe connection (usually 2" diameter)
Fill pipe with spill containment
Overfill prevention valve
Leak detection port
Level gauge connection (manual dipstick or automatic level gauge)
Emergency vent (pressure relief)
Interstitial space monitoring via:
Vacuum or pressure system
Liquid/brine detection sensor
Electronic monitoring system
Access chamber / tank sump for valves and fittings
Fill point containment box
Vent caps with flame arrestors
Tank gauging system (ATG – Automatic Tank Gauge)
Overfill alarms
Excavation: Designed to prevent floatation (ballast if needed)
Backfill: Washed pea gravel or sand per manufacturer’s spec
Concrete slab: May be required for vehicle load areas
Setbacks: As per fire and environmental codes
Hydrostatic or pneumatic pressure testing
Leak test of interstitial space
Calibration of tank gauge
Inspection and certification by approved authority
₹ 210000 / Piece Get Latest Price
| Storage Capacity | 10000 L |
| Storage Capacity(L) | 10000 L |
| Tank Material | Carbon Steel |
| Color | gray |
| Shape | Horizontal |
| Country of Origin | Made in India |
Minimum order quantity: 1 Piece
Type: Horizontal cylindrical, double-walled
Installation: Underground (buried)
Capacity: (1,000 Liter to 1,00,000 Liters
Material:
Primary: Steel or fiberglass-reinforced plastic (FRP)
Secondary containment: FRP jacket or steel with corrosion-resistant coating
Environmental Compliance: EPA (U.S.), local environmental protection regulations
Fire Safety: NFPA 30 / 31 / 385
Double-wall construction for leak detection and secondary containment
Corrosion protection:
External: Protective coating or cathodic protection (for steel tanks)
Internal: Epoxy lining (optional)
Manways: 1 or 2 units (typically 600 mm or 24 inches diameter)
Internal Baffles: As required to minimize fuel movement (sloshing)
Anchor points: For buoyancy resistance
Fuel inlet/outlet connections (e.g., 2" to 4" threaded or flanged)
Vent pipe connection (usually 2" diameter)
Fill pipe with spill containment
Overfill prevention valve
Leak detection port
Level gauge connection (manual dipstick or automatic level gauge)
Emergency vent (pressure relief)
Interstitial space monitoring via:
Vacuum or pressure system
Liquid/brine detection sensor
Electronic monitoring system
Access chamber / tank sump for valves and fittings
Fill point containment box
Vent caps with flame arrestors
Tank gauging system (ATG – Automatic Tank Gauge)
Overfill alarms
Excavation: Designed to prevent floatation (ballast if needed)
Backfill: Washed pea gravel or sand per manufacturer’s spec
Hydrostatic or pneumatic pressure testing
Leak test of interstitial space
Calibration of tank gauge
Inspection and certification by approved authority
₹ 230000 / Piece Get Latest Price
| Storage Capacity(L) | 10000 L |
| Shape | Cylindrical |
| Color | Silver |
| Tank Material | Stainless Steel |
| Country of Origin | Made in India |
Minimum order quantity: 1 Piece
Type: Vertical cylindrical or horizontal cylindrical
Installation: Above-ground (typical)
Capacity: From 1,000 liters to 100,000+ liters
Orientation: Vertical preferred for space efficiency
Design Codes (as applicable):
API 650 (for welded steel tanks)
ASME Section VIII Div. 1 (for pressurized or heated tanks)
Local or in-house engineering standards
Tank Shell and Bottom:
Mild Steel (MS)
Stainless Steel 304 or 316 (optional, if corrosion resistance is needed)
Roof: Cone or dome type, same material as shell
Nozzles/Fittings: MS or SS, as per corrosion resistance and process requirements
Welding: SMAW or MIG/TIG depending on material
Insulation (optional):
Rock wool / Mineral wool / PU foam (typically 50–100 mm)
Cladding: Aluminum or Galvanized Steel Sheet
Heating System (for oils with high melting points like palm oil):
Internal steam coil (MS or SS)
Electrical heating pads or trace heating
Temperature control sensor and local temperature gauge
Manhole: Top or side access, bolted cover
Level Indicator:
Mechanical float type
Sight glass
Radar/ultrasonic (optional)
Temperature Sensor: Thermowell with bimetallic thermometer or RTD
Inlet/Outlet Nozzles: 2"–4" flange or threaded
Drain Valve: Located at tank bottom or side
Ventilation: Free vent with insect screen or pressure/vacuum relief valve
Sampling Point: Optional, as per design
Internal Surface:
MS tanks: Unlined or with anti-corrosive epoxy coating
SS tanks: 2B finish or mill finish
External Surface:
Painted for MS (primer + top coat)
Polished or unpolished for SS
Cleaning:
Manual or semi-automatic (CIP not required unless specified)
Foundation: RCC (Reinforced Cement Concrete) pad
Supports:
Skirt support or leg support (for vertical tanks)
Saddle support (for horizontal tanks)
Anchor Bolts: As per seismic/wind load calculations
Hydrostatic or Pneumatic Testing: As per pressure rating
Weld Inspection: Visual, NDT (if required)
Paint/Coating Thickness Testing: As per coating specification
Leak Test: For outlet/drain nozzles and manways
Agitator/Mixer: For blending or homogenization
Overflow Alarm: Float switch or electronic sensor
Load Cells: For weight-based inventory control
Tank Farm Integration: SCADA/PLC system (if automated)